HLK-LD6002B (60 GHz vitals radar)
hlk-ld6002b
wh_aa520f730d388573
sensor
Companion 60 GHz vitals radar (1x owned w/ testboard), planned Node A1 addition. Native HR, limited HRV, RR, micro-motion flag, target distance. Best-in-class effort/strain (physiological-load) proxy. Built on Andar ADT6101P with vendor vitals algorithm.
Attention
No reports yet. Opens and MCP reads still count above, including zero.
Last look 2026-11-28 04:26
Good for
- heart rate / RR / limited HRV
- effort/strain proxy
- recovery dynamics
- breath rate (native)
Not for
- raw IF access (processed only)
- muscle-specific sensing
Spec
| freq | 60 GHz |
|---|---|
| interface | UART 1,382,400 baud TinyFrame |
| output | HR, HRV (limited), RR, micro-motion flag, distance |
| power | 3.3V |
| chip | Andar ADT6101P |
| source | docs/MODULES.md §2 |
Pinout
Supply
Mouser query: HLK-LD6002B
Chips on board
Seen in
Hi-Link HLK-LD6002 60 GHz FMCW vitals radar module
LD6002 Radar
ld6002-radar
Reads an HLK-LD6002 60 GHz radar over USB-serial UART and reports, per window, the radar's own heart-rate, breathing-rate, distance, target-count and presence-flag outputs, the target positions it streams (x/y metres in the radar's own frame, not room coordinates), plus frame and checksum counts. Values the radar did not report in the window are null. The vitals are the module's on-chip estimates, not medical measurements; no pose, no bounding box.
| Hardware | pi-zero-2w, v0-appliance |
|---|---|
| Binary | cog-ld6002-radar-arm |
- Version
- v0.2.0
- aarch64 sha256
- 134ddb6a73fc22a49e208abf05f43e27d76288f92a085c0c5bd3664d7a01e6d5
- aarch64 sig
- 989f5b509b354637…505fc7a7b5a70607
- armv7 sha256
- b761eedf1f94ec7e80611b2ec7d5b2e12a68e30699adba3173acab65d2f7424c
- armv7 sig
- cc98f9eb5403995c…367a764cc285590a
- Signed by
- 6aae63e06748…d12eca15
cog install ld6002-radar — the binary is verified against the WeaveLogic release key (6aae63e06748…d12eca15) via the signed registry at /registry.json. The cog then serves its API on port ?.